Blast furnace freezer requirements

Jan 02, 2021

When the ice reaches the required thickness (the thickness can be arbitrarily selected by the operator/user), the hot air discharged from the compressor is re-introduced into the wall of the ice maker to replace the low-temperature liquid refrigerant. In this way, a thin film of water is formed between the ice and the wall of the evaporation tube. This water film will act as a lubrication when the ice falls freely into the groove below by gravity. The water produced during the ice picking cycle will return to the water storage tank through the porous tank, which also prevents the wet ice from being discharged by the machine.

1. The chilled water pump in the water storage tank of the blast furnace freezer continuously circulates through the plate or compartment evaporator;

2. After the compressor is in operation, it undergoes suction-compression-exhaust-condensation (liquefaction)-throttling-and then vaporizes in the evaporator at a low temperature of -10 to -18 degrees. Chilled water continuously condenses into an ice layer on the surface of the lower evaporator at a water temperature of 0 degrees. When the ice layer has condensed to a certain thickness, after the evaporation temperature of the refrigerant reaches the set temperature of the temperature control, the defrost solenoid valve is turned on and the ice is deiced in the form of a heat pump, and the next cycle is realized.